What this lesson covers
In gas chromatography, an inert carrier gas carries the vaporised sample through a column with a liquid stationary phase. Free notes and 15 questions answered.
Describe the principles of thin-layer chromatography (TLC), column chromatography (CC), and gas chromatography (GC), including the roles of stationary and mobile phases
Explain how retention time and Rf values are used to identify components in a mixture
Compare TLC, CC, and GC in terms of their applications, advantages, and limitations
Interpret chromatograms from TLC and GC to identify and quantify components
Revise Right Mocks '26
AQA A-Level Chemistry mock draft, 26–31 Oct. Draft coverage: Chemistry 7405/1 · Paper 1. Reviewed for an original-practice sitting; check student availability before registering. Marking and results will follow later, after separate approval. Eligible new accounts receive a five-day Pro trial when signup email verification completes. Previous trials keep their original expiry. After expiry, new papers need Pro unless you have an explicitly confirmed free sitting offer for this event. That offer adds no Pro time or AI learning. Saved attempts and released results remain readable. No card or automatic charge.
Use this lesson to stay inside Chromatography (A-level only) while connecting the detail back to the wider Organic chemistry topic.
Stationary phase: The fixed medium through which a mixture travels during chromatography. In TLC it is a polar solid (silica or alumina) coated on a plate; in CC it is a polar solid packed in a column; in GC it is a non-volatile liquid coated on an inert solid inside a column.
Mobile phase: The medium that carries the mixture through the stationary phase. In TLC and CC it is a liquid solvent; in GC it is an inert carrier gas such as nitrogen or helium.
Rf value: The ratio of the distance travelled by a component to the distance travelled by the solvent front in TLC or paper chromatography. Used to identify components by comparison with known standards under identical conditions.
Retention time: The time taken for a component to travel from the injection point to the detector in gas chromatography. Each compound has a characteristic retention time under fixed conditions, allowing identification by comparison with known standards.
Revision notes
Read the core explanations from Chromatography Types: TLC, CC & GC (Part 3/4) before testing yourself from memory.
1. Why Chromatography Matters at A-Level
You already know from earlier in this series that all chromatography techniques share one core idea: components in a mixture distribute themselves between a stationary phase and a mobile phase, and those that interact more strongly with the stationary phase travel more slowly. What changes between TLC, column chromatography, and gas chromatography is the physical form of those two phases — and that change has enormous consequences for what each technique can do.
AQA expects you to be able to describe how each technique works, interpret the data it produces, and evaluate which technique is most appropriate for a given purpose. This lesson builds each technique from the ground up, then brings them together for direct comparison.
2. Thin-Layer Chromatography (TLC)
Picture a small rectangular plate — typically glass or aluminium — coated with a thin, uniform layer of silica gel or alumina. That coating is the stationary phase, and it is polar. A tiny spot of the mixture is placed near the bottom of the plate, which is then stood upright in a shallow pool of solvent (the mobile phase). The solvent climbs the plate by capillary action, carrying the components of the mixture with it.
Components that interact more strongly with the polar stationary phase (through hydrogen bonding or dipole interactions) are held back and travel a shorter distance. Components that are more soluble in the mobile phase travel further. When the solvent front approaches the top of the plate, the plate is removed and the solvent front is marked immediately to minimise error from evaporation.
Many spots are colourless and invisible to the naked eye. To visualise them, the plate is placed under ultraviolet (UV) light — compounds that absorb UV appear as dark spots on a fluorescent background — or the plate is developed with a chemical locating agent such as iodine vapour or ninhydrin spray (for amino acids).
Worked example: Calculating and Using an Rf Value
A TLC plate is run with a solvent. The solvent front travels 8.0 cm from the baseline. A component travels 5.6 cm. Calculate the Rf value and suggest how it could be used to identify the compound.
$R_f = \dfrac{\text{distance travelled by component}}{\text{distance travelled by solvent front}}$ — This ratio is always between 0 and 1. A value close to 1 means the component strongly favours the mobile phase; close to 0 means it strongly favours the stationary phase.
$R_f = \dfrac{5.6 \text{ cm}}{8.0 \text{ cm}}$ — Both distances are measured from the same baseline (the original spot position), so units cancel.
$R_f = 0.70$ — 5.6 ÷ 8.0 = 0.70. This is a dimensionless number — do not include units.
Compare Rf = 0.70 with a data table of known Rf values run under identical conditions. — If a known standard also gives Rf = 0.70 on the same plate with the same solvent, the compound is likely that substance. Running a reference standard alongside the unknown on the same plate is the most reliable approach.
Answer: $R_f = 0.70$ (no units). Identify by comparing with known standards run under identical conditions on the same plate.
TLC is fast, cheap, and requires only a small sample. It is widely used to monitor the progress of a reaction — if the spot for the starting material disappears and a new spot appears, the reaction has proceeded. It can also check the purity of a product: a pure compound produces a single spot, whereas a mixture produces multiple spots.
3. Column Chromatography (CC)
Column chromatography scales up the principle of TLC. Instead of a flat plate, a vertical glass column is packed with a polar stationary phase — typically silica gel or alumina — and the mixture is loaded onto the top. Solvent (the mobile phase) is then poured through continuously, and components elute (wash out) from the bottom of the column at different times.
The component that interacts least with the stationary phase elutes first; the component that interacts most strongly elutes last. Fractions are collected from the bottom of the column in separate containers, and each fraction can then be analysed (for example by TLC) to confirm which component it contains.
Unlike TLC, column chromatography is a preparative technique — it actually separates and collects the individual components in usable quantities, rather than merely identifying them. This makes it the method of choice when a chemist needs to purify a synthesised compound after a reaction.
Feature
TLC
Column Chromatography
Scale
Analytical (tiny sample, ~µg)
Preparative (mg to g quantities)
Stationary phase
Silica/alumina on a plate
Silica/alumina packed in a column
Mobile phase
Liquid solvent (climbs by capillary action)
Liquid solvent (flows down by gravity or pressure)
Output
Rf value for identification
Separated fractions collected for further use
Speed
Minutes
Minutes to hours
Primary use
Monitor reactions, check purity
Purify and isolate compounds
4. Gas Chromatography (GC)
Gas chromatography works on the same partition principle, but both phases are fundamentally different from TLC and CC. The mobile phase is an inert carrier gas — typically nitrogen or helium — and the stationary phase is a high-boiling-point liquid coated onto an inert solid inside a long, coiled capillary column held inside an oven.
The sample is injected as a liquid into a heated injection port, where it vaporises instantly. The carrier gas sweeps the vapour through the column. Components partition between the carrier gas and the liquid stationary phase: those that are more soluble in the stationary phase spend more time there and take longer to reach the detector. Those that are less soluble in the stationary phase — or that are more volatile — travel through faster.
The detector — most commonly a flame ionisation detector (FID) — produces an electrical signal each time a component reaches it. This signal is plotted against time to produce a gas chromatogram: a series of peaks, each representing one component. The position of each peak (its retention time) identifies the component; the area under each peak is proportional to the amount of that component present.
Reading the chromatogram above: three peaks appear at approximately 2, 5, and 8 minutes. Each peak corresponds to one component eluting from the column. The peak at 5 minutes has the largest area, indicating that component is present in the greatest proportion. To identify each component, the retention times are compared with those of known reference compounds run under identical conditions.
Quantitative analysis is possible because peak area is proportional to the amount (or concentration) of each component. By calculating the fraction of the total peak area that each individual peak represents, the percentage composition of the mixture can be determined.
Worked example: Calculating Percentage Composition from a GC Chromatogram
A GC chromatogram shows three peaks with areas of 240, 360, and 120 arbitrary units. Calculate the percentage of the mixture represented by each component.
$\text{Total area} = 240 + 360 + 120 = 720 \text{ arbitrary units}$ — The total area represents 100% of the mixture. Adding all three peak areas: 240 + 360 = 600, then 600 + 120 = 720.
$\% \text{ component 2} = \dfrac{360}{720} \times 100 = 50.0\%$ — 360 ÷ 720 = 0.500, multiplied by 100 gives 50.0%. This is the largest peak and the most abundant component.
Gas chromatography separates the components of a mixture, but on its own it can only identify them by comparing retention times with known standards. When GC is coupled to a mass spectrometer (GC-MS), each component that elutes from the column is fed directly into the mass spectrometer, which produces a fragmentation pattern — a mass spectrum — unique to that compound.
This combination is extremely powerful: GC provides the separation and the retention time, while the mass spectrometer provides an unambiguous molecular fingerprint. GC-MS is used in forensic science (identifying drugs or accelerants), environmental monitoring (detecting trace pollutants), and food analysis (checking for adulterants or contaminants).
AQA expects you to know that GC-MS allows identification of components even when no reference retention time is available, because the mass spectrum can be matched against a library of known spectra. This makes GC-MS far more definitive than GC alone for unknown samples.
6. Comparing All Three Techniques
Now that each technique has been covered individually, it is worth drawing them together. The key differences come down to the nature of the phases, the type of output, and the purpose each technique serves.
Feature
TLC
Column Chromatography
Gas Chromatography
Stationary phase
Polar solid (silica/alumina on plate)
Polar solid (silica/alumina in column)
Non-volatile liquid on inert solid
Mobile phase
Liquid solvent
Liquid solvent
Inert carrier gas (N₂ or He)
Sample requirement
Any soluble compound
Any soluble compound
Must be volatile or vaporisable
Output
Rf value (spots on plate)
Separated fractions collected
Chromatogram with retention times and peak areas
Analytical or preparative?
Analytical
Preparative
Analytical
Quantitative?
Not reliably (spot intensity is approximate)
No (fractions collected, not measured)
Yes (peak area proportional to amount)
Typical application
Monitor reactions, check purity
Purify and isolate compounds
Identify and quantify components in volatile mixtures
7. Exam Technique and Common Mistakes
Chromatography questions on AQA papers tend to fall into three categories: describe how a technique works, interpret data from a chromatogram, or evaluate which technique is most suitable for a given purpose. Each requires a different approach.
When asked to describe how TLC works, examiners want a sequential account: spot applied to plate, plate placed in solvent, solvent rises by capillary action, components separate based on their relative affinities for stationary and mobile phases, solvent front marked, Rf values calculated. Avoid vague phrases like "the components move at different speeds" without explaining why.
In normal-phase TLC, a less polar component is less strongly attracted to the polar stationary phase, so it spends a greater fraction of time moving with the mobile phase and usually travels further, giving a higher Rf value under the same conditions.
When asked to evaluate which technique to use, structure your answer around the purpose (analytical vs preparative), the nature of the sample (volatile or non-volatile), and whether quantitative data is needed. A conclusion is required for full marks on an evaluate question.
Worked example: How to Read a Chromatogram Safely
Use retention time or Rf only under stated conditions.
Use peak area to compare relative amount, not retention time.
Treat a single TLC spot as evidence of purity, not absolute proof.
Sources and content standards
Published by Revise Right. Use the official specification reference to check the requirements for your course. Content updated: 2026-09-05.
The sample is vaporised and swept by an inert carrier gas, such as nitrogen or helium, through a coiled column containing a high-boiling-point liquid stationary phase. Components more soluble in the stationary phase take longer to reach the detector, giving longer retention times.
How does thin-layer chromatography work?
A spot of the mixture is placed near the bottom of a plate coated with polar silica gel or alumina, and the plate is stood in a solvent. The solvent climbs by capillary action, and components that interact more strongly with the stationary phase travel a shorter distance.
What is the carrier gas in gas chromatography?
The mobile phase in GC is an inert carrier gas, typically nitrogen or helium. It sweeps the vaporised sample through a long, coiled capillary column containing a high-boiling-point liquid stationary phase held inside an oven.
What does elute mean in chromatography?
To elute means to wash out from the bottom of the column. In column chromatography, the component that interacts least with the stationary phase elutes first and the component that interacts most strongly elutes last, so fractions are collected separately.
What is the difference between TLC and column chromatography?
TLC is an analytical technique that uses a tiny sample to give Rf values, so it is used to monitor reactions and check purity. Column chromatography is preparative: it separates and collects components in usable quantities, so it is used to purify a synthesised compound.
How do you find percentage composition from a gas chromatogram?
Peak area is proportional to the amount of each component, so divide each peak area by the total area and multiply by 100. For peaks of 240, 360 and 120 arbitrary units, the total is 720, giving 33.3%, 50.0% and 16.7%.
Why is GC-MS better than gas chromatography alone?
GC alone can only identify components by comparing retention times with known standards. In GC-MS, each component is fed into a mass spectrometer that gives a fragmentation pattern, which can be matched against a library of known spectra even when no reference retention time is available.
How are colourless spots seen on a TLC plate?
Many TLC spots are colourless, so the plate is placed under UV light, where compounds that absorb UV appear as dark spots on a fluorescent background. A chemical locating agent such as iodine vapour, or ninhydrin spray for amino acids, is applied.
Why is the solvent front marked immediately in TLC?
The solvent front is marked as soon as the plate is removed to minimise error from evaporation. The distance travelled by the solvent front is needed to calculate the Rf value of each component.
How can TLC check the purity of a product?
A pure compound produces a single spot on a TLC plate, whereas a mixture produces multiple spots. A single spot should be treated as evidence of purity, not absolute proof.
How is TLC used to monitor a reaction?
TLC can monitor the progress of a reaction: if the spot for the starting material disappears and a new spot appears, the reaction has proceeded. It is widely used for this because it is fast, cheap and requires only a small sample.
What is a flame ionisation detector?
A flame ionisation detector, FID, is the most common detector in gas chromatography. It produces an electrical signal each time a component reaches it, and this signal is plotted against time to give a gas chromatogram of peaks.
What is a preparative chromatography technique?
A preparative technique actually separates and collects individual components in usable quantities, instead of merely identifying them. Column chromatography is preparative, working with mg to g quantities, which makes it the method of choice to purify a synthesised compound.
What is GC-MS used for?
GC-MS is used in forensic science to identify drugs or accelerants, in environmental monitoring to detect trace pollutants, and in food analysis to check for adulterants or contaminants. The mass spectrum gives an unambiguous molecular fingerprint for each separated component.
How does polarity affect the Rf value in TLC?
In normal-phase TLC, a less polar component is less strongly attracted to the polar stationary phase. It spends a greater fraction of time moving with the mobile phase and usually travels further, giving a higher Rf value under the same conditions.