A reversed heat engine is a device that uses work to push thermal energy from cold to hot, the opposite of its natural flow. Notes and 13 questions answered.

Reversed Heat Engines: Principles and Uses is part of Thermodynamics and engines (A-level only) in A Level AQA Physics.

7 min

Reading time

16

Lessons in this topic

A Level AQA

Pathway

Reviewed by Revise Right

Content review

What this lesson covers

A reversed heat engine is a device that uses work to push thermal energy from cold to hot, the opposite of its natural flow. Notes and 13 questions answered.

  • Explain the basic operating principle of a reversed heat engine, distinguishing it from a forward heat engine
  • Describe how a heat pump and a refrigerator each use work input to transfer thermal energy against a temperature gradient
  • Compare the purpose and energy flow direction in heat pumps versus refrigerators
  • Evaluate the coefficient of performance for heat pumps and refrigerators and interpret what high or low values mean physically

Key ideas to keep in view

Use this lesson to stay inside Thermodynamics and engines (A-level only) while connecting the detail back to the wider Engineering physics (A-level only) topic.

  • Reversed heat engine: A thermodynamic device that uses an external work input to transfer thermal energy from a cold reservoir to a hot reservoir, operating in the opposite direction to a heat engine.
  • Coefficient of performance (COP): A dimensionless ratio expressing the useful thermal energy transferred per unit of work input for a reversed heat engine. A higher COP indicates greater efficiency of energy transfer.
  • Heat pump: A reversed heat engine used to transfer thermal energy into a warm space (the hot reservoir) from a cooler environment, with the useful output being the heat delivered to the warm space.
  • Refrigerator: A reversed heat engine used to extract thermal energy from a cold space (the cold reservoir), keeping it cool, with the useful output being the heat removed from the cold space.

Revision notes

Read the core explanations from Reversed Heat Engines: Principles and Uses before testing yourself from memory.

1. Running an Engine Backwards

A heat engine takes thermal energy from a hot source, converts some of it into useful work, and dumps the rest into a cold sink. Now ask yourself: what happens if you reverse that process entirely? Instead of extracting work from a temperature difference, you supply work to create a temperature difference. That is the core idea behind a reversed heat engine.

Think of it like pushing water uphill. Normally water flows downhill on its own, releasing energy. To push it uphill you must put energy in. Thermal energy naturally flows from hot to cold — a reversed heat engine uses work to push it the other way, from cold to hot.

This single idea underpins two everyday devices: the refrigerator and the heat pump. They share the same operating principle but serve opposite purposes, and distinguishing between them is exactly what AQA examiners test.

2. Energy Flow in a Reversed Heat Engine

Picture a simple energy flow diagram. In a forward heat engine, thermal energy $Q_H$ flows in from the hot reservoir, work $W$ flows out, and waste heat $Q_C$ flows into the cold reservoir. In a reversed heat engine, the arrows on $W$ and $Q_C$ flip: work $W$ is supplied into the device, thermal energy $Q_C$ is extracted from the cold reservoir, and a larger quantity of thermal energy $Q_H$ is delivered to the hot reservoir.

This relationship is non-negotiable — it follows directly from conservation of energy. Notice that $Q_H$ is always greater than $W$ alone, because the device also harvests $Q_C$ from the cold side. That is why reversed heat engines can deliver more thermal energy to a space than the electrical energy they consume.

3. Refrigerators — Keeping Things Cold

A refrigerator's purpose is to maintain a cold space at a temperature below its surroundings. Work is supplied (by an electric motor, for instance) to extract thermal energy $Q_C$ from the cold interior and reject a larger quantity $Q_H$ to the warm kitchen. The cold space is the useful side here — you want to keep it cold.

The useful output of a refrigerator is $Q_C$: the thermal energy removed from the cold reservoir. You are paying for the work $W$, and you want as much cooling as possible per joule of work spent.

A domestic refrigerator might have a $\text{COP}_{\text{ref}}$ of around 2 to 4, meaning it removes 2–4 J of thermal energy from the food compartment for every 1 J of electrical energy consumed. The remaining energy, plus the work input, is rejected as heat at the back of the appliance — which is why the back of a fridge feels warm.

4. Heat Pumps — Delivering Warmth Efficiently

A heat pump uses the same physical mechanism as a refrigerator, but the goal is reversed: you want to deliver thermal energy to a warm space, not remove it from a cold one. A ground-source heat pump, for example, extracts thermal energy from the cool ground outside a building and delivers a larger quantity of thermal energy into the building's heating system.

Here the useful output is $Q_H$ — the heat delivered to the hot reservoir (the building). You are still paying for work $W$, but you benefit from both the work energy and the harvested environmental energy $Q_C$.

This is the key advantage of a heat pump over a simple electric heater. An electric heater converts 1 J of electrical energy into exactly 1 J of thermal energy — its COP is 1 by definition. A heat pump with a COP of 3 delivers 3 J of thermal energy for every 1 J of electrical energy consumed, because it harvests 2 J from the cold environment for free.

5. Comparing Refrigerators and Heat Pumps

Both devices are reversed heat engines operating on the same energy flow: work in, heat extracted from cold side, heat rejected to hot side. The difference is entirely about which side you care about. Recognising this distinction is a common exam demand.

FeatureRefrigeratorHeat Pump
PurposeKeep a cold space coldKeep a warm space warm
Useful output$Q_C$ (heat removed from cold reservoir)$Q_H$ (heat delivered to hot reservoir)
COP formula$\text{COP}_{\text{ref}} = Q_C / W$$\text{COP}_{\text{HP}} = Q_H / W$
COP relative to 1Can be greater or less than 1Always greater than 1
Typical applicationFood storage, air conditioningBuilding heating, ground-source systems

Notice the mathematical link between the two COPs. Since $Q_H = Q_C + W$, dividing through by $W$ gives $\text{COP}_{\text{HP}} = \text{COP}_{\text{ref}} + 1$. The heat pump COP is always exactly 1 more than the refrigerator COP for the same device operating under the same conditions.

6. Worked Calculation — Applying the Principles

Exam questions on reversed heat engines almost always give you two of the three quantities ($Q_H$, $Q_C$, $W$) and ask you to find the third, then calculate a COP. The step-by-step below models the method you should use every time.

Worked example: Reversed Heat Engine — Finding COP and Energy Values

A heat pump delivers 4500 J of thermal energy to a building. The work input to the pump is 1500 J. Calculate: (a) the thermal energy extracted from the cold reservoir, and (b) the coefficient of performance of the heat pump. [4 marks]

  1. $Q_H = 4500 \text{ J}, \quad W = 1500 \text{ J}$ — Write down what you are given before touching any formula. This prevents substitution errors. [M1]
  2. $Q_H = Q_C + W \Rightarrow Q_C = Q_H - W = 4500 - 1500 = 3000 \text{ J}$ — Rearrange $Q_H = Q_C + W$ to isolate $Q_C$. The cold reservoir supplies 3000 J — this is the environmental energy harvested. [A1]
  3. $\text{COP}_{\text{HP}} = \dfrac{Q_H}{W}$ — The useful output of a heat pump is $Q_H$, so that goes on top. [M1]
  4. $\text{COP}_{\text{HP}} = \dfrac{4500}{1500} = 3.0$ — 4500 divided by 1500: $4500 / 1500 = 3.0$. COP is dimensionless — no units. [A1]
  5. $\text{COP}_{\text{HP}} = 3.0 > 1$ ✓ and $Q_H = Q_C + W = 3000 + 1500 = 4500 \text{ J}$ ✓ — A heat pump COP must always exceed 1. Energy conservation checks out. If your COP were less than 1 for a heat pump, recheck which quantity you placed in the numerator.

Answer: (a) $Q_C = 3000$ J; (b) $\text{COP}_{\text{HP}} = 3.0$

7. Practical Context and Uses

AQA requires you to know the basic principles and uses of heat pumps and refrigerators — detailed knowledge of the working fluid cycle or specific components is not required. What you do need is the ability to describe what each device does, explain why it is thermodynamically advantageous, and apply the energy equations.

Heat pumps are used in domestic and commercial heating. A ground-source heat pump extracts thermal energy from soil or groundwater (which stays at a relatively stable temperature year-round) and delivers it to a building's central heating system. Because the COP is typically 3–4, a household can receive 3–4 kJ of heating for every 1 kJ of electrical energy paid for.

Refrigerators and freezers maintain food at low temperatures by continuously extracting thermal energy from the cold interior and rejecting it to the kitchen. Air-conditioning systems operate on the same principle: they act as refrigerators for a room, extracting thermal energy from the indoor air and rejecting it outside.

8. Exam Technique and Common Mistakes

Reversed heat engine questions are reliable mark-earners if you approach them methodically. The most common source of lost marks is confusing which quantity is the useful output — and therefore which quantity goes in the numerator of the COP expression.

For 'explain' or 'evaluate' style questions, examiners award marks for linking the physics to the context. Saying 'the COP is 3' earns fewer marks than saying 'the COP is 3, meaning 3 J of thermal energy is delivered to the building for every 1 J of electrical energy consumed, because the device also harvests 2 J from the cold ground'.

Mastering reversed heat engines comes down to two things: keeping the energy conservation equation $Q_H = Q_C + W$ at the front of your mind, and always being clear about which side of the device is the 'useful' side before writing a COP expression — that single distinction separates the refrigerator from the heat pump at every level of exam question.

Frequently asked questions

How does a ground-source heat pump work?

A ground-source heat pump extracts thermal energy from the cool ground, soil or groundwater outside a building, which stays at a relatively stable temperature year-round, and uses work to deliver a larger quantity of thermal energy into the building's central heating system. With a COP typically of 3–4, a household receives 3–4 kJ of heating per 1 kJ of electrical energy.

Why is a heat pump better than an electric heater?

A heat pump is better than an electric heater because it delivers more thermal energy than the electrical energy it consumes. An electric heater has a COP of 1, while a heat pump with a COP of 3 delivers 3 J for every 1 J of electrical energy, harvesting 2 J from the cold environment.

What is the difference between a heat pump and a refrigerator?

A heat pump and a refrigerator share the same operating principle but serve opposite purposes. A refrigerator's useful output is the heat removed from the cold space, keeping it cold, while a heat pump's useful output is the heat delivered to the warm space, such as a building, keeping it warm.

How does air conditioning work?

Air conditioning works on the same principle as a refrigerator: it acts as a refrigerator for a room. Work is supplied to extract thermal energy from the indoor air, which is the cold reservoir, and that energy plus the work input is rejected outside.

What is a reversed heat engine?

A reversed heat engine is a device that uses work to push thermal energy from cold to hot, the opposite of its natural flow. Work is supplied, thermal energy is extracted from the cold reservoir, and a larger quantity of thermal energy is delivered to the hot reservoir. Refrigerators and heat pumps are both reversed heat engines.

What is the energy equation for a reversed heat engine?

The energy equation for a reversed heat engine is Q(H) = Q(C) + W: the heat delivered to the hot reservoir equals the heat extracted from the cold reservoir plus the work supplied. This follows from conservation of energy, and it means the heat delivered is always greater than the work alone.

Why does the back of a fridge feel warm?

The back of a fridge feels warm because that is where the refrigerator rejects heat. It extracts thermal energy from the cold food compartment and rejects a larger quantity, equal to that extracted energy plus the electrical work input, to the warm kitchen.

What is the COP of a typical domestic fridge?

A domestic refrigerator might have a coefficient of performance of around 2 to 4. That means it removes 2–4 J of thermal energy from the food compartment for every 1 J of electrical energy consumed, with a higher value meaning more cooling per joule of work supplied.

What is the COP of an electric heater?

An electric heater has a coefficient of performance of exactly 1 by definition, because it converts 1 J of electrical energy into exactly 1 J of thermal energy. A heat pump with a COP of 3 delivers 3 J of thermal energy for every 1 J consumed, because it harvests 2 J from the cold environment.

How can a heat pump give out more energy than it uses?

A heat pump gives out more thermal energy than the electrical energy it consumes because it does not create energy: it also harvests thermal energy from the cold reservoir. The heat delivered equals the heat extracted from the cold side plus the work supplied, so the heat delivered always exceeds the work input.

What is the difference between a heat engine and a reversed heat engine?

A heat engine takes thermal energy from a hot source, converts some into useful work and dumps the rest into a cold sink, extracting work from a temperature difference. A reversed heat engine does the opposite: work is supplied to extract thermal energy from the cold reservoir and deliver a larger quantity to the hot reservoir.

How do you find the heat extracted from the cold reservoir of a heat pump?

The heat extracted from the cold reservoir equals the heat delivered to the hot reservoir minus the work input, from rearranging Q(H) = Q(C) + W. A heat pump that delivers 4500 J with a work input of 1500 J extracts 3000 J from the cold reservoir, giving a COP of 4500 ÷ 1500 = 3.0.

Why is the COP of a heat pump always greater than 1?

The COP of a heat pump is always greater than 1 because the heat it delivers equals the heat extracted from the cold reservoir plus the work supplied. Since the delivered heat is always more than the work input, the ratio of delivered heat to work exceeds 1, the key advantage over a simple electric heater.